Pulse 280 Specifications Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
www.ti.com
Operational Description of HRPWM
Table 5. Duty Cycle Range Limitation for 3 and 6 SYSCLK/TBCLK Cycles
PWM Frequency
(1)
3 Cycles 6 Cycles SYSCLKOUT
(kHz) Minimum Duty Minimum Duty
200 0.6% 1.2%
400 1.2% 2.4%
600 1.8% 3.6%
800 2.4% 4.8%
1000 3.0% 6.0%
1200 3.6% 7.2%
1400 4.2% 8.4%
1600 4.8% 9.6%
1800 5.4% 10.8%
2000 6.0% 12.0%
(1)
System clock - T
SYSCLKOUT
= 10 ns
System clock = TBCLK = 100 MHz
If the application demands HRPWM operation in the low percent duty cycle region, then the HRPWM can
be configured to operate in count-down mode with the rising edge position (REP) controlled by the MEP.
This is illustrated in Figure 7. In this case, low percent duty limitation is no longer an issue. However, there
will be a maximum duty limitation with same percent numbers as given in Table 5 .